To look for a specific item then please use the search facility by clicking
here
Buildings
6.5 Internal doors
- at least 925mm clear opening of one leaf on main circulation routes. On
double doors a 2/3 - 1/3 split can achieve this. At least 825mm for other
doors (750mm minimum)
- 300mm unobstructed space to side of leading edge
- level landings either side (avoid single steps)
- vision panel to give minimum zone of visibility from 900mm to 1500mm from
floor level
- door closers to have minimum practicable opening pressure
- door handles to be easily usable and clearly distinguishable from door
- kick-plate recommended depth 400mm.
Building
entrances, Doors - General design features, Principal
entrance doors, Non automatic doors, Double
doors, Door handles, Automatic
doors, Glass Doors, Revolving
Doors, Doormats