6.5 Principal entrance doors

See also 6.6 Lobbies and Corridors.

Non automatic doors

Diagram showing a plan of a single door minimum clear opening 925mm. A return wall is shown adjacent the opening side of the door and a gap of 300mm minimum is shown between the return wall and the line of swing of the leading edge of the door.

Double doors

at least one of the pair should provide the minimum clear opening width. Doors across circualtion routes should have visibility glazing.

Diagram showing an elevation of a set of double doors with kick plates at the bottom of the doors and a vision panel in each door. The minimum zone of visibility being indicated by two parallel dotted lines measuring 900mm and 1500mm from the floor level. The vision panels in these doors extend above and below this minimum zone.

Building entrances, Doors - General design features, Internal doors, Door handles, Automatic doors, Glass Doors, Revolving Doors, Doormats